6 Specifications ar
e subject to change without notice UDM40 DS ENG 261110
UDM40
rph, krph
Diagnostics The display flashes when the
limits of the display range
are exceeded and the data
are updated up to 20%
of the rated display range.
Burn-out: Only temperature inputs
TC Opening of probe’s
c
onnection: EEE indication
R
TD Opening of probe’s
connection: EEE indication
probe’s short circuit:
-EEE indication.
BQTFx Exceeding of frequency
range: Err indication
Digital filter
Filter operating range 0 to 9999
Filtering coefficient 1 to 32
Scaling Selection of min value
of the input range.
Selection of max value of
the input range.
Selection of decimal point
position.
Selection of min
display value.
Selection of max display
value.
Linearization
Points Up to 16
Input range Selectable by every
single point
Output range Selectable by every
single point
UdmSoft Software for
programming UDM40
by means of PC (Windows 95,
98se, ME, XP) by means of
serial port RS485 and
r
elevant connection cable.
The software is available in
English, Spanish, Italian,
German, French. See also
“Programming of
UDM40 by means of PC” .
Min / Max storage Automatic storage
(
in the EEPROM) of the
m
inimum and maximum
m
easured value from the
previous memory reset
Password Numeric code max 4 dgt
2 levels of data protection.
1st level
0 to 4999 completly protected.
2
nd level 5000 to 9999 access to
p
rogramming is protected .
Alarm set-points are directly
programmable from the
measuring mode.
Measurement selection Depending on the module:
measuring range and type of
probe (resistance, RTD
thermoresistance, TC
thermocouple) or measuring
type (
TRMS or DC).
Function (only BQTFx) Displayed function of
channel A and B:
F1: scaled value of channel A;
F2: 1/A;
F3: A-B;
F4: (A-B)/B*100;
F5: A/B;
F6: B/(A+B)+100;
F7: rotation sensing.
Integration time selection Automatic or from 100.0 to
999.9 ms only in the current
and voltage measurement
(BQTFx excluded).
Scaling factors
Operating mode Electrical scale compression,
displayed scale
compression/expansion
(max. 2 without filter, up to
10 with filter)
Electrical range Programmable within the
whole measuring range
Decimal point position Programmable within the
display range
Displayed range of the variable Pr
ogrammable within the
display range
Pulse per revolution BQTFx only: programmable
from 1 to 9999
Input engineering unit BQTFx only: programmable
among Hz, kHz, rpm, krpm,
Software functions
AC/DC voltage 90 to 260V (standard)
18 to 60V (on r
equest)
(24 to 48V AC/DC ± 25%
according to UL)
DC voltage only 10 to 28V (on r
equest)
(12 to 24V DC
± 15%
according to UL)
Energy consumption 30V
A/12W (90 to 260V)
20VA/12W (18 to 60V)
7.5W (10 to 28V)
Supply Specifications