CARLO GAVAZZI UDM 40 - PROGRAMMING Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měření, testování a kontrola CARLO GAVAZZI UDM 40 - PROGRAMMING. UDM40 Datasheet Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 14
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Specifications are subject to change without notice UDM40 DS ENG 261110 1
Multi-input modular instrument
4-DGT LED
0.1% RDG basic accuracy
TRMS AC current and voltage measurements
AC/DC current measurements; selectable full scales
(200µA to 5A)
AC/DC voltage measurements; selectable full scales
(200mV to 500V)
°C or °F temperature measurements
(Pt100-250-500-1000, Ni100, TC J-K-S-T-E)
Resistance measurements; selectable full scales
(20 to 20k)
Dual rate, speed, frequency and period measurement
(0.001Hz to 50kHz)
Up to 4 independent alarm set-points (optional)
20mA/10VDC analog output (optional)
Serial port RS485 or RS232 (optional)
MODBUS, JBUS communication protocol
Front protection degree: IP67, NEMA12
LED display, selectable colour (red, amber, green)
Product Description
µp-based digital panel
meter, 4-DGT LED indicator,
for current, voltage, temper-
ature, resistance, rate, fre-
quency, speed and period
measurements. Measuring
ranges and functions easily
programmable from the key-
pad or from the PC by
means of optional UdmSoft
software. UDM
40 includes
storage min-max functions
and double level protection
password. Housing for panel
mounting with front protec-
tion degree: IP67, NEMA12.
Digital Panel Meters
Modular Indicator and Controller
Type UDM40
Type Selection
Slot A (measuring inputs)
LSX:
signal inputs:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
LSE/
LSF: signal inputs: + AUX:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
HSX: signal inputs:
0.2-2-5A DC/AC;
20-200-500V DC/AC
TRX: signal inputs: TC tem
-
perature probes (J-K-
S-T-E, Pt100-250-500-
1000) and resistance
(0.02-0.2-2-20k)
TF1: 0.001Hz to 50kHz for
DC signals: PNP
,
NPN, NAMUR, TTL,
free of voltage, con
-
tacts, voltages up to
14VDC
TF2: 0.001Hz to 50kHz for
AC signals: pick-up,
voltages up to
500VAC
Slot B (communication)
XX:
None
SX: Serial port RS485
SY: Serial port RS232
A
V
(*):
Single analogue output,
0 to 20mA DC and
0 to 10V DC
Slot C (communication and alarm)
XX:
None
R1:
Single relay output,
(AC1-8AAC, 250VAC)
R2
:
:
Dual r
elay output,
(AC1-8AAC, 250VAC)
R4
:
:
Dual relay output,
(AC1-
8AAC, 250VAC)
+ dual
open collector output
(NPN, 100mA)
R5
:
:
4 relay outputs
(AC1-5AAC, 250VAC)
AV(*):
Single analogue output,
0 to 20mA DC
and
0 to 10V DC
Slot D (power supply)
H: 90 to 260V AC/DC
L:
18
to
60V
AC/DC
(24 to 48V AC/DC ±
25% according to UL)
3:
10
to
28V
DC
(12 to 24V DC ± 15%
according to UL)
Options
XX: None
TX: Tropicalization
Model
Slot A
Slot B
Slot C
Slot D
Options
How to order
UDM40 XXX XX XX X XX
The alarm status can be coupled to the different
colour of the display
Linearization of V, A and Hz inputs up to 16 points
How to order
UdmSoft-kit
UdmSoft-kit: software plus communication cable for pro-
gramming UDM40 by means of PC.
UdmSoft: software for programming UDM35/40/60 by
means of PC, downloadable from www.carlogavazzi.com.
(*): The two analogue
outputs cannot be
used at the same
time. It is possible to
plug in only one
module by instru-
ment.
Zobrazit stránku 0
1 2 3 4 5 6 ... 13 14

Shrnutí obsahu

Strany 1 - Type UDM40

Specifications are subject to change without notice UDM40 DS ENG 261110 1•Multi-input modular instrument4-DGT LED• 0.1% RDG basic accuracy• TRMS

Strany 2 - Input specifications

10 Specifications are subject to change without notice UDM40 DS ENG 261110UDM40Temp. measur. from thermoresistanceTemp. measur. from thermocoupleRe

Strany 3

Specifications are subject to change without notice UDM40 DS ENG 261110 11UDM40Auxiliary commandFig. 19BQ TF1Wiring diagrams (cont.)Max 500VACPick

Strany 4 - 4 Specifications ar

12 Specifications are subject to change without notice UDM40 DS ENG 261110UDM40BO R4: dual relay output + dual open collector output: the load resi

Strany 5 - Output specifications

Specifications are subject to change without notice UDM40 DS ENG 261110 13UDM40:-to program values;-to select functions;- to scroll display pages.

Strany 6 - Supply Specifications

14 Specifications are subject to change without notice UDM40 DS ENG 261110UDM40BP LPower supply:18 to 60V AC/DCBO R4Dual relay output +Dual open co

Strany 7 - General Specifications

2 Specifications are subject to change without notice UDM40 DS ENG 261110UDM40Analogue inputs Channels and variableBQ LSX module 1, mA and V DC/ACB

Strany 8 - Used calculation formulas

Specifications are subject to change without notice UDM40 DS ENG 261110 3UDM40Module Inputs Type Accuracy Temp. drift Min. indication (<) Max.

Strany 9 - Wiring diagrams

4 Specifications are subject to change without notice UDM40 DS ENG 261110UDM40Input impedances and overloads(*) Maximum measuring current generated

Strany 10 - Wiring diagrams (cont.)

Specifications are subject to change without notice UDM40 DS ENG 261110 5UDM40RS422/RS485 (on request) Module: BR SXSerial output Bidirectional (s

Strany 11

6 Specifications are subject to change without notice UDM40 DS ENG 261110UDM40rph, krphDiagnostics The display flashes when thelimits of the displa

Strany 12 - RS1,2,3...N

Specifications are subject to change without notice UDM40 DS ENG 261110 7UDM40Safety StandardsSafety EN 61010-1, IEC 61010-1Connections Screw type

Strany 13 - Engineering Units

8 Specifications are subject to change without notice UDM40 DS ENG 261110UDM40Available modules Possible module combinationsOnly for TRMS Measureme

Strany 14 - 14 Specifications ar

Specifications are subject to change without notice UDM40 DS ENG 261110 9UDM40Wiring diagramsProcess signal wiring diagramsCurrent measurements4-w